Solenoid Operated

Ashish Engineering Services - Solenoid Operated

Solenoid Operated

The G-Series Solenoid Operated Directional Valves incorporate electronic circuits to enable adjustment of the spool shifting time. A special spool shape that minimizes shock is used, shock caused by the actuator starting and stopping, as well as vibration due to oil hammering. The shifting time of conventional Solenoid Operated. Shockless, Directional Valves is constant and cannot be adjusted.

Features / specifications

 

Descriptions

 

Model Numbers

 

G-DSG-01-???-?-50

G-DSG-03-???-?-50

Max. Flow *1

L/min.

10, 20, 30, 40

40, 60, 80

Max. Operating Pres. *2

Kgf/cm2

250

250

Max. T-Line Back Pres.

Kgf/cm2

160

160

 

Electric Power Supply

Voltage

24 V DC (21 – 28 V DC Included Ripple):

Use a stable Power supply

Input Power at 24V

36 W

36 W

Shifting signal, low speed operation halt signal (can be used in common with electric power supply).

Voltage

5 – 48 V DC (Use a stable power supply)

Current

Constant at 10 mA (A Constant-current circuit is used)

Input interface

Sink Type, Source Type

Shifting time range

(for ON and OFF)

 

 

 

0.1 – 1 s

0.3 – 1 s

Low speed operation flow

rate (min. flow rate) range

(for SOL a and )L/min.

 

 

0.5 – 5

1 – 10

Low speed operation flow rate (min. flow rate) hold time

 

Max. 60 s (after 60 seconds, the flow rate decreases gradually.)

Ambient Temperature

 

0 – 50 °C (32 – 122°F) with circulated air

 

Approx. Mass

Single Solenoid

2.1Kg.

5.3 Kg.

Double Solenoid

3.0 Kg.

7.5 Kg.