In-Line Check Valve

Ashish Engineering Services - In-Line Check  Valve

In-Line Check Valve

These valves allow free flow in one direction and prevent flow in the reverse direction. Cracking pressure specified is the pressure required to open the valve and allow free flow. Rated flow is the approximate flow rate, when there is a free flow pressure drop of maximum 3 Kgf/cm2, the fluid has a specific gravity of 0.85, a kinematic viscosity of 20cSt, and the cracking pressure is 0.35 Kgf/cm2.

Features / specifications

Model Number

Rated Flow * L/min.

Max. Operating Pressure Kgf/cm2

Cracking Pressure Kgf/cm2

Mass Kg.

CIT-02-?-2080

12

 

 

210

0.35

2.0

3.5

5.0

0.10

CIT-03-?-2080

30

0.18

CIT-06-?-2080

80

0.65

CIT-10-?-2080

200

2.1